Precautions for the Operation & Use of Mixed Flow Vertical Turbine Pump
Mixed flow vertical turbine pump is a commonly used industrial water pump. It adopts double mechanical seals to reliably prevent water leakage. Due to the large axial force of large pumps, thrust bearings are used. The structure design is reasonable, the lubrication is sufficient, the heat dissipation is good, and the service life of the bearings is long. ;Because the motor and the water pump are integrated, there is no need to carry out labor-intensive and time-consuming assembly procedures on the axis of the motor, transmission mechanism, and water pump at the installation site, and the on-site installation is convenient and fast.
Precautions for the operation & use of mixed flow vertical turbine pump
1. During trial operation, check the link parts to ensure that there is no looseness in each link part.
2. Electrical appliances and instruments are working normally; there must be no leakage in the pipelines of oil, gas and water systems; the pressure and hydraulic pressure are normal.
3. Frequently check whether there are floating objects near the water inlet to prevent the water inlet from being blocked.
4. The temperature of rolling bearings in mixed flow vertical turbine pump s should not exceed 75 degrees.
5. Pay attention to the sound and vibration of the pump at any time, and stop the pump immediately for inspection if any abnormality is found.
6. The temperature of the oil in the gearbox should be normal
The above points that need to be paid attention to during the operation of the mixed flow vertical turbine pump . If you have any unclear points during the operation, please contact Credo Pump in time.